INSTALLATION INSTRUCTION
Before Installation
Test run the unit with proper power supply. Refer to the operation instruction section in the Owner's Manual
Operation & Installation. Make sure all the controls operate correctly then disconnect the power supply of the unit.
WARNING!
Moving parts may cause personal injury. Be careful when test the unit. Do not operate the unit with exterior cover
removed.
STEP 1 · STICK SPONGE (SEALING STRIP) AND SPONGE ON THE OUTDOOR UNIT
1. Before sticking, clean up the sundries at the sticking
position (as shown in Figure 1) of the chassis of the
outdoor unit to ensure that the sticking position is
clean;
2. Take out one piece of sponge (sealing strip) and
three pieces of sponge from the accessories, and
tear off the paper on the glue surface and align at
the edge of the position as shown in Figure 1 to
stick the sponge.
If the sponge (sealing strip) is damaged or not stuck
on the proper position, you must replace it with a
new one and stick it properly;
3. Check whether the sponge (sealing strip) and the
sponge are tightly adhered, and ensure that they
will not fall off.
STEP 2 · SELECTING AN INSTALLATION LOCATION & INSTALLING THE ROOF TOP
AIR CONDITIONER
Your air conditioner has been designed for use in recreational vehicles. Check the roof of the vehicle to determine
if it can support both the roof top unit and the ceiling assembly without additional support. Make sure the interior
ceiling mounting area will not interfere with existing structures. Once the location for your air conditioner has
been determined. A reinforced and framed roof. Hole must be cut (if there is no hole, please refer to CASE B) or
you may use existing vent holes (See CASE A).
CASE A
If a roof vent is already present in the desired mounting location for the air conditioner the following steps must be
performed:
Remove all screws which secure the roof vent to the vehicle. Remove the vent and any additional trim. Carefully
remove all chalking from around the opening so the surface is clear.
It may be necessary to seal some of the old roof vent mounting screw holes which may fall outside of the air
conditioner basepan gasket.
Examine the roof opening size, if the opening is small than 400x400mm, the opening must be enlarged.
Sticking position
of sponge
(sealing strip)
Sticking position of
three
of
pieces
sponge
Figure 1