At this time, select the First Using function in
the System Function, and then operate accor-
ding to the following:
a. According to the instructions, connect the
test connector on the fuel outlet pipe and in-
sert it into the Fill Port.
b. Then, run the function.
c. When there have liquid out from the test
adaptor, stop it. If not stop, it'll stop automa-
tically after 30s.
d. Now it can use normally.
Note: if there have no liquid out, you can run
it again.
Connect the test adaptor to the outlet pipe
Insert it into the Fill Port
Select the Setting Function
Select the First Use function
4) The buzzer rings continually when there is no
fuel pressure.
The machine has fuel-lack warning function
and it will ring when the liquid in the fuel tank
is lack, and then automatically switch off the
fuel pump and injectors and returns to the
stop state. Supply the detergent or test liquid
to stop ringing.
5) Draining the test liquid in glass tube tho-
roughly requires pressing the DRAIN icon more
times.
The solenoid valves will stop automatically af-
ter 15 seconds and it is necessary to drain more
times if there is more liquid.
8.2 Precautions
1) Do not place anything on the control panel
to prevent from breaking the measuring cup
because it is made from vulnerable.
2) Do not disconnect hose before the system
pressure reaches "0".
3) Always ensure that the provided power su-
pply is well contacted with ground safely.
4) The unit is designed with warning function.
When the level switch checks the liquid inside
the tank less than the lowest line, the unit will
utter the warning sound and meanwhile stop
the fuel pump and injectors automatically,
and then the unit returns to the stop state. The
unit will stop warning until the liquid is supplied
enough, at this time pressing the ENTER key will
run the unit again.
5) Clean the control panel in time and Keep
the pulse signal cable away from the liquid.
· 30 ·
REF.54392