Turn the filter over and rinse the air filter under running water. Allow the water to flow through
•
the filter in the opposite direction to the airflow. Set the filter to one side and allow it to air-
dry completely before reinstalling it.
Fig. 1.
Switch off the unit and
remove the two air filters.
Warning!
The surface of the evaporator must not be touched with bare hands, as this can result in
damage to the slats and injury.
6.0 DECOMMISSIONING
6.1 STORAGE
Long-term storage – If the unit will not be used for an extended period of time, it is advisable that
it be cleaned and dried completely. Store the unit according to the following steps:
Remove the plug from the socket. Remove the exhaust hose and the window spare part
•
stored with the unit.
Drain the remaining water from the unit.
•
Clean the filter and let it dry completely.
•
Replace the filter.
•
The unit must stand upright during storage.
•
Store the machine in a ventilated, dry, non-corrosive environment and in a safe place indoors.
•
ATTENTION:
The evaporator inside the system must be dried before packing to avoid damage to components
and moulds. Disconnect the unit from the mains and place it in a dry, open location for several
days to dry. Another way of drying the system is to switch the machine on, set it to a low-wind
ventilation mode and maintain this condition until the drainpipe becomes dry to keep the inside
of the enclosure dry and prevent mould growth.
6.2 TRANSPORT
1.
Before commissioning, set upright and leave to stand still for MIN. 12 HOURS! This protects
the compressor, extends its service life considerably and thus prevents a loss of cooling
capacity.
2.
The air conditioning unit must always be placed on the floor with PARTICULAR CARE!
Otherwise, cracks may appear in the base plate and the condensate tray, causing condensate
to drip onto the floor.
We do not provide warranty services for damage caused by improper use!
34
Fig. 2.
Rinse the air filter
under running water.
www.DEUBAXXL.de