Dustguard™ System Water Filter Cleaning (Optional); Hopper Hydraulic Lifting System Oil Level Check - Advance SW4000 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

DUSTGUARD™ SYSTEM WATER FILTER CLEANING (OPTIONAL)
NOTE
To prevent water from lowing out when cleaning the
ilter, turn on the dust guard system and empty the
system tank (24).
1.
Drive the machine on a level ground.
2.
Turn the ignition key (61) to "0" and engage the parking
brake.
From under the machine (A, Fig. 20), reach the water ilter
3.
assembly (B) of the dust guard system.
4.
Unscrew and remove the transparent cover (C) with the
gasket (D), then remove the ilter strainer (E).
5.
Clean and install them on the holder (F).
NOTE
Install the gasket (C) and the ilter strainer (E) in
the housings of the cover and of the ilter assembly
holder.

HOPPER HYDRAULIC LIFTING SYSTEM OIL LEVEL CHECK

WARNING!
Procedure to be performed with the hopper (11)
fully retracted.
1.
Turn the ignition key (61) to "0" and engage the parking
brake.
2.
Open the battery compartment hood (18) with the handle
(41) and fasten it with the support rod (52).
3.
Check that the oil level in the tank (51) is between the
minimum (MIN) and maximum (MAX) marks shown in
igure 21.
4.
If necessary, add oil through the plug (A, Fig. 21), using the
oil speciied in Technical Data paragraph.
5.
Remove the support rod (52) and close the hood (18).
INSTRUCTIONS FOR USE
A
B
Figure 20
Figure 21
1464818000 - SW4000
ENGLISH
F
D
E
C
P100651
P100607
29
Tabla de contenido
loading

Este manual también es adecuado para:

9084403010

Tabla de contenido