CONNECTION OF THE HOB FOR 1773
Mains
Connection
230 V~ 50/60 Hz
1 phase +N
400 V~ 50/60Hz
2 phases + N
400 V~ 50/60Hz
2 phases +
(NL)
230 V~ 50/60 Hz
2 phases
230 V~ 50/60 Hz
3 phases
(BE)
* calculated with the simultaneous factor following the standard EN 60 335-2-6
CONNECTION OF THE HOB FOR 1776
Mains
Connection
230 V~ 50/60 Hz
1 phase +N
400 V~ 50/60Hz
2 phases + N
400 V~ 50/60Hz
2 phases + 2N
(NL)
400 V~ 50/60Hz
3 phases + N
230 V~ 50/60 Hz
2 phases
230 V~ 50/60 Hz
3 phases
(BE)
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Supply cord
3 x 2,5 mm
4 x 1,5 mm
5 x 1,5 mm
2N
3 x 2,5 mm
4 x 1,5 mm
Supply cord
3 x 4 mm
4 x 2,5 mm
5 x 2,5 mm
5 x 1,5 mm
3 x 4 mm
4 x 2,5 mm
equipped with a faulty earth connection.
– 1775
– 1777
/2
/2
Supply cord
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
– 1778
/2
/3
Supply cord
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
25
/2
Wiring diagram
Wiring diagram
Circuit braker
25 A *
16 A *
16 A *
25 A *
16 A *
Circuit braken
40 A *
25 A *
25 A *
16 A *
40 A *
25 A *