The installer is held to respect the legislation and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Warning: Do not apply sealant between the bottom side of the hob and worktop
Fitting - installing:
• The cut out sizes are:
Type
Cut size
Width
1773
560
/2
1775
750
/2
1776
750
/2
1777
890
/2
1778
850
/3
• Ensure that there is a distance of 50 mm between the hob and the wall or sides.
• The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or divider must stand higher than the
hob.
• The piece of furniture or the support in which the
hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used
to fix them, must be able to resist temperatures of
up to 100 °C.
• The mural rods of edge must be heat-resisting.
• Not to install the hob to the top of a not ventilated
oven or a dishwasher.
• To guarantee under the bottom of the hob casing
a space of 20 mm to ensure a good air
circulation of the electronic device.
• If a drawer is placed under the work, avoid to put
into this drawer flammable objects
example: sprays) or not heat-resistant objects.
• Provide a ventilation opening from 4 mm just
under the worktop over a width of min. 600 mm for sufficient cooling of the hob.
Glass size
Depth
Width
Depth
490
654
490
804
490
804
390
914
490
904
Stick the gasket (2) two
millimeters from the external
edge of the glass, after removing
the protection sheet (3).
Thickness
524
7
524
7
524
7
414
7
524
7
(for
23
Cut size of flush mouting
Width
Depth
650
520
800
520
800
520
910
410
900
520
Radius
4
4
4
4
4