Condensate discharge parameters programming.
Push the SET key for 10 seconds to enter the parameters configuration menu: the display will show in sequence the set point
value, the code of the first modifiable parameter (C8) and its value).
Only if strictly necessary, use the UP and/or DOWN keys to change the displayed parameter value.
Press the SET key to store the previously changed parameter value or to browse the parameters without changing them.
15 seconds after the last performed operation, the controller will return automatically to the normal operation mode.
PARAMETER
C8
C9
NOTE: Changes entered for timing values will be effective only after exiting the programming, while changes to other variables will
be immediately effective.
Please remember that eventual changes to the configuration parameters of the machine could negatively affect its efficiency. Thus,
changes have to be arranged in collaboration with the manufacturer.
IT'S FORBIDDEN TO MODIFY THE OTHER CONFIGURATION PARAMETERS OF THE ELECTRONIC
CONTROLLER WITHOUT THE SERVICE CENTER'S AUTHORIZATION AND COLLABORATION.

ANOMALY WARNING

The controller is capable to recognize certain types of anomalies to the drying circuit. In such cases, an alarm message will blink on
the display, alternated to the current dew – point value.
MESSAGE
(BLINKING)
HtA
Ht2
LtA
PF1
ESA
ES2
ASt
Note: PF1 has priority on all other alarm messages.
DESCRIPTION
Delay between condensate discharges
Time required for condensate
discharge
WARNING FOR USER:
CAUSE
High Dew – point value
(delayed alarm)
Very high Dew – point value
(immediate alarm)
Low Dew – point value
Interruption or short circuit on
the PTC probe input line
Energy saving mode
activated
Series of alarms very close to
each other
RANGE
1 ÷ 999 (min)
1 ÷ 999 (sec)
OUTPUTS
Alarm output ON
Refrig. Compressor output
OFF
Fan output ON
Discharge cycle standard
Alarm output ON
Refrig. Compressor output
OFF
Fan output OFF
Discharge cycle standard
Alarm output ON
Refrig. Compressor output
OFF
Fan output OFF
Discharge cycle standard
Alarm output OFF
Refrig. Compressor output
OFF
Fan output OFF
Discharge cycle standard
Alarm output ON
Refrig. Compressor output
OFF
Fan output ON
Discharge cycle standard
23
SET VALUE
1
1
ACTIONS
Resettable by switching off
the control board when
dew-point returns to preset
range.
If it persists call our Service
Centre.
Automatic reset when dew-
point returns to preset
range.
If it persists call our Service
Centre.
Resettable by switching off
the control board and
replacing the faulty probe.
Call our Service Centre.
No action necessary.
Automatic Reset
Call our Service Centre.