Flush-Mounted Installation - Superrollo GW60 Instrucciones De Montaje

Idiomas disponibles
  • ES

Idiomas disponibles

i
9. Flush-mounted installation
1.
If an existing roller shutter system
is being replaced, first remove the
old belt winder.
◆ Fully lower the roller shutters
until the slats are completely
closed.
◆ Remove the old belt winder and
reel up the belt.
Risk of injury due to pre-stressed
springs in the old belt winder.
The spring unit can snap back in
an uncontrolled manner when
it is removed. Hold the spring
unit firmly when loosening the
belt and allow it to recoil slowly
until the spring unit has completely
unwound.
2.
Prepare the belt.
◆ Cut off the belt approx. 20 cm
underneath the belt housing.
◆ Wrap around the end of the belt
by approx. 2 cm and cut a short
slot in the centre. This will sub-
sequently enable you to hook
the belt onto the winding wheel.
EN
63

Hide quick links:

loading

Este manual también es adecuado para:

Sr10060