3.3
Installation with open expansion vessel - outline
A
Valve
B
Minimum thermometer
C
Circulator
D
Open expansion vessel
E
Bleeder
1
A.C.S. electric valve
3
Hot domestic water
When installing a DERO fireplace with an open ex-
pansion vessel, a number of safety requirements
should be taken into account.
When installing the radiators, do not place area
thermostat valves on all radiators. Part of the insta-
llations (radiators) must always be open to enable
the heater to dissipate any overheating or overs-
peed.
It is mandatory to include an expansion vessel
(open or closed) in the installation.
It is advisable to install a thermostat that will cut
the circulator whenever the water in the boiler is
F
Emptying valve
G
Heater drainage
I
ACS KIT
H
Auto filling and anti-backflow valve
2
Exchanger
4
Fluxostat
below 50ºC. This will avoid condensation when ligh-
ting the heater.
It is advisable for all installation components
(safety valve, circulator) to be installed on the ba-
ckflow.
Industrias Hergom S.A. declines all liability connec-
ted with the installation. The installer must comply
with local regulations in order to install the system
correctly.