6. Equipment usage:

Ensure grounding is connected (grounding Rod) as indicated in the attached figure.
Check with an electrician in case of any doubts.
GROUNDING SYMBOL
WARNING: Never connect the 230 voltage output of the equipment to a
building or house (not even during a power outage). The return of the main
network would clash with the generator's voltage and cause serious damage to the
equipment or even a fire.
WARNING: Do not connect in parallel with other generator, both will be
damaged and will be a fire hazard.
NOTE: Do not connect an extension to the exhaust.
NOTE: If a cable extension is needed, make sure you use a good quality
rubber extension (as per IEC245 or equivalent standards) and appropriate section:
 60m cable length: use a 1.5mm
 100m cable length use a 2.5mm
NOTE: Devices that use an engine such as compressors, water pumps, saws,
radials, etc. require up to 3 times more power for startup. For example, a 500 W
water pump would need a 1500 W generator for startup. Verify that charges upon
connection do not exceed the maximum power of the group according to this
indication.