Electric Connection
1. Make sure the mains voltage you want to use corresponds to the
voltage of the appliance. Please check the rating label for detailed
specifications.
2. Connect the appliance to a properly installed grounded socket. A signal
will sound indicating that the appliance is ready for use.
Using the Appliance
Turning Appliance On / Off
• Press the POWER
button to turn on the appliance. The appliance
is pre-set to "Cooling" mode and the temperature is 25 °C. If operation
has been stopped without disconnecting the plug, all previously set
operating mode and temperature settings will be retained. The control
lamps indicate this setting.
• Press the POWER
button again to turn off the appliance.
Compressor Safety Appliance
If operation is interrupted, the safety appliance for the compressor is acti-
vated. This prevents operation of the compressor for approx. 3 minutes, in
order to relieve the pressure in the cooling circuit. This is not a malfunc-
tion of the appliance. Therefore, wait at least 3 minutes, before switching
the appliance on again.
Control Panel
Button
Control lamp
-
POWER
TEMP +
-
TEMP −
-
COOL (Cooling)
MODE
DEHUM (Dehumidifying)
FAN (Fan)
HIGH (High speed)
SPEED
LOW (Low speed)
TIMER
TIMER
-
W.F
Operating Modes
Use the MODE
button to select one of the following operating modes:
• Cooling (COOL)
• Dehumidifying (DEHUM)
• Fan (FAN)
The control lamps indicate the setting.
Operating Mode "Cooling"
In this operation mode, you can adjust the fan speed and the temperature
as desired.
NOTE:
To operate the appliance with the compressor, the set temperature must
be lower than the current room temperature.
Operating Mode "Dehumidifying"
• This operating mode does not support any further settings.
• The appliance will change the set temperature automatically to room
temperature minus 2 °C.
• The fan will operate at the lowest speed setting.
• The appliance will cool the room and extract the humidity from the air.
Setting the Temperature
Use the TEMP +
or TEMP −
temperature. Select a temperature between 16 °C and 31 °C.
CL3671_IM_new2
Explanation
Turn on / off
Increase temperature
Reduce temperature
Select operating mode
Set fan speed
Timer operation
Water must be emptied.
buttons in "Cooling" mode to set the
Setting the Fan
In "Cooling" and "Fan" modes you can set the fan speed with 2 different
settings. Press the SPEED
button accordingly.
Setting the Air Outlet
Adjust the fins to regulate the direction of discharged air.
• Turn one of the fins in order to direct the air upwards / downwards.
Timer (Automatic Timer)
Use the timer function to set the power-on and power-off times of the
appliance. Select a time between 1 and 24 hours.
Using the Timer Function for Automatic Power-On
1. Press the POWER
button to turn on the appliance.
2. Select the operating mode, temperature and fan speed for the appli-
ance to operate in or at when powered on at the pre-set time.
3. Press the POWER
button to turn off the appliance.
4. Press the TIMER
button. The control lamp TIMER lights. The number
of hours flashes.
5. You can set the desired number of hours with the buttons TEMP +
and TEMP − . The setting changes rapidly when you hold down the
respective button. Confirm your setting with the TIMER
the display is flashing. Otherwise you will exit the setting mode. In this
case, the setting will not be applied.
Using the Timer Function for Automatic Power-Off
1. Press the POWER
button to turn on the appliance.
2. Press the TIMER
button during operation. The control lamp TIMER
lights. The number of hours flashes.
3. Set the TIMER
as described in the above item 5.
NOTE:
• Press the TIMER
button again if you want to deactivate the
TIMER function.
• You may also cancel the timer function at any time by pressing the
POWER
button to turn the appliance on / off.
Emptying the Water Tank
The appliance integrates a water tank for collecting condensation. When the
water tank is full, the pilot lamp "W.F" lights up. The compressor switches off
in each operation mode. The fan keeps running independent of this.
CAUTION:
Do not transport the appliance while the water tank is full. Water could
get into the appliance.
For continued operation with the compressor, you must empty the water
tank. For this, you need a floor cloth, a flat bowl with a capacity for approx.
1.5 litres of water and the water hose supplied with the appliance.
1. Disconnect the mains plug from the wall socket.
2. Place the floor towel and the flat bowl underneath the water outlet. If
possible, set the bowl on a lower level than the appliance.
3. Remove the rubber cap and the plug. Keep the parts for later use.
4. Connect the water hose to the water outlet of the appliance. Place the
end of the hose in the bowl.
5. After the water has been discharged, remove the water hose.
Close the water outlet on the appliance again with the plug and
the rubber cap to ensure the condensation water cooling circula-
tion.
Terminating Operation
1. Press the POWER
button to turn off the appliance.
2. Disconnect the mains plug from the wall socket.
button while
31
14.12.2016