EuroLite LB-12 LED-BAR Manual Del Usuario página 24

Idiomas disponibles

Idiomas disponibles

Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
Connect the effect to the mains and switch it on via the POWER-switch.
Attention: After every 10 LB-12 LED-BARs, the fixtures must have a renewed connection with the power
mains.
Stand Alone-operation
In the Stand Alone mode, the FUTURELIGHT LB-12 LED-BAR can be used without controller. You can do
without a controller as the features a built-in microphone, which provides automatic sound control.
Disconnect the FUTURELIGHT LB-12 LED-BAR from the controller and set DIP-switch 10 to ON and DIP-
switch 11 to OFF to select Stand Alone sound control mode.
Master/Slave-operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the FUTURELIGHT LB-12 LED-BAR you can find an XLR-jack (DMX Out) and an XLR-
plug (DMX In), which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a balanced microphone lead.
Connect the DMX OUT-jack with the DMX IN-plug of the next device.
Set the DIP-switch, as listed in table 1, for the master-device. When the unit is running in Master/Slave
mode, all slave-devices must be set to DMX address 001, and DIP-switches 11 and 12 have to be set to
OFF.
International
L
N
24/55
00027030.DOC, Version 1.2
loading