Daewoo DAX135-1600 Manual De Uso página 12

Hidrolavadora de alta presión
Idiomas disponibles

Idiomas disponibles

4. After motor and water supply are turned off, trigger gun to depressurize system.
CAUTION: NEVER turn water supply off before turning motor off. Serious damage could occur to the
pump and or motor.
WARNING! NEVER disconnect high pressure discharge hose from machine while system is pressu-
rized. To depressurize, turn motor off, turn water supply off and squeeze gun trigger 2-3 times.
5. After each use, wipe all surfaces of the pressure washer with a clean, damp cloth.
6. Storage
Do not store pressure washer outdoors.
Do not store pressure washer where it might freeze.
TIPS FOR EXTENDING THE LIFE OF YOUR PRESSURE WASHER
1. Never operate unit without water.
2. Pressure washer is not meant to pump hot water. Never connect to hot water supply – this will
significantly reduce life of the pump.
3. Using detergent other than others brand may cause damage to pump components (o-rings,
etc.).This also applies to chemicals such as bleach, dish soap, etc.
4. Never operate unit for more than one (1) minute without spraying water. Resulting heat buildup will
damage pump.
5. Before adjusting nozzle's pressure (high-to-low or low-to-high) release trigger.
Failure to do so will reduce life of o-rings in lance.
3. POSSIBLE PROBLEM AND SOLUTION
Symptom
No detergent
suction –units
with tanks
No detergent
Suction – units
with attachable
applicators
Unit begins to
smoke
Possible cause(s)
1. Lance nozzle is not in low pres
sure
2. High pressure exten-
sion hose or high pressure
hose is too long.
3. Injector clogged on pump
Detergent applicator is clogged
Overheated, overloaded or
damaged motor
Corrective Action(s)
1. Slide lance nozzle into low
pressure position
2. Remove high pressure exten-
sion hose or use high pressure
hose shorter than 25 feet.
3. Call the dealer
1. Clean applicator with warm
water.
2. Replace applicator
Turn off unit and call the dealer
12