mode.
2. The VS-840EX is in the stop condition.
Start Playing back, and Start Recording the track that status are
the record standby mode.
If the transport switch [REC] was pressed out of the recording
condition,
the VS-840EX transmits as the device ID 7FH.
RECORD EXIT
Status
Data Bytes
F0H
7FH,Dev,06H,07H
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
07H
RECORD EXIT
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the recei-
ving device or 7FH, the VS-840EX exits from the record condi-
tion.
If the transport switch [REC] was pressed while recording, the
VS-840EX transmits as the device ID 7FH.
MMC RESET
Status
Data Bytes
F0H
7FH,Dev,06H,0DH F7H
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
0DH
MMC RESET
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the recei-
ving device or 7FH, the VS-840EX resets all communication
channels related with MMC.
When powered on the VS-840EX transmits as the device ID
7FH.
WRITE
Status
Data Bytes
F0H
7FH,Dev,06H,40H,ccH,ddH,eeH,,,ffH,,,
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
40H
WRITE
ccH
Information Bytes follows the command
ddH
The name of the writable Information Field
eeH
Information Field Format
:
:
ffH
Field names and data
:
:
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the recei-
ving device or 7FH, the VS-840EX writes the data to the speci-
fied infomation field.
The VS-840EX does not transmit the message.
MASKED WRITE
Status
Data Bytes
F0H
7FH,Dev,06H,41H,04H,ddH,eeH,ffH,ggH F7H
Byte
Description
F0H
Status of Exclusive Message
182
Status
F7H
Status
Status
F7H
Status
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
41H
MASKED WRITE
04H
Number of Bytes follows the command
ddH
The name of the masked type writable Information
Field
eeH
Byte number to write in the Bit Map
ffH
Bit location of the bit map byte to change
ggH
New data to write to the specified bit map byte
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the recei-
ving device or 7FH, the VS-840EX writes the data to the speci-
fied bit map byte.
The VS-840EX does not transmit the message.
LOCATE (MCP)
Format 1 - LOCATE[I/F]
Status
Data Bytes
F0H
7FH,Dev,06H,44H,02H,00H,nnH
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
44H
LOCATE(MCP)
02H
Number of Bytes
00H
ÒI/FÓ sub command
nnH
Information Field
08H, 09H, 0AH, 0BH, 0CH, 0DH, 0EH, 0FH)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the recei-
ving device or 7FH, the VS-840EX locates the selected time loca-
tion stored to the specified information field.
The VS-840EX does not transmit the message.
Format 2 - LOCATE[TARGET]
Status Data Bytes
F0H
7FH,Dev,06H,44H,06H,01H,hrH,mnH,scH,frH,ffH F7H
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
44H
LOCATE(MCP)
06H
Number of Bytes
01H
ÒTARGETÓ sub command
hrH, mnH, scH, frH, ffH
Standard Time with Sub Frame
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the recei-
ving device or 7FH, the VS-840EX locates the specified time
location received from the command.
If the efficient Maker of the locate switch is pressed or when
moved, the VS-840EX transmits as the device ID 7FH.
MOVE
Status
Data Bytes
F0H
7FH,Dev,06H,4CH,02H,ddH,ssH
Byte
Description
F0H
Status of Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
4CH
MOVE
02H
Number of Bytes
Status
F7H
Status
Status
F7H
Tabla de contenido
loading

Tabla de contenido