HAMPTON BAY San Marino Manual Del Propietário página 8

Ventilador de techo de 0,91 m
Idiomas disponibles

Idiomas disponibles

Installing Fan to
the Outlet Box
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR OTHER PERSONAL INJURY, MOUNT
FAN ONLY TO AN OUTLET BOX MARKED AC-
CEPTABLE FOR FAN SUPPORT AND USE THE
MOUNTING SCREWS PROVIDED WITH THE
OUTLET BOX.
1. Pass the 120-volt supply wires through the
center hole in the ceiling mounting bracket
as shown in Figure 10.
2. Install the ceiling mounting bracket on the
outlet box by sliding the mounting bracket
over the two screws provided with the outlet
box. When using close-to-ceiling mounting,
it is important that the mounting bracket be
level. If necessary, use leveling washers (not
included) between the mounting bracket and
the outlet box. Note that the flat side of the
mounting bracket is toward the outlet box
(Figure 10).
WHEN MOUNTING THE FAN ON A SLOPED
CEILING, THE STANDARD BALL/DOWNROD
MOUNTING METHOD MUST BE USED. MAKE
SURE THE MOUNTING BRACKET SLOTS ARE
ON THE LOWER SIDE BY SLIDING THE MOUNT-
ING BRACKET FROM THE TOP DOWN.
6.
UL Listed
Outlet Box
Slide Mounting
Bracket Over
Screw Heads
120V Wires
3. Securely tighten the two mounting screws.
4. Carefully lift the assembly up to the ceiling
mounting bracket and hang the fan on the
hook provided by utilizing one of the holes
at the outer rim of the ceiling canopy (Fig-
ure 11). If using standard mounting, seat the
hanger ball in the mounting bracket socket.
Make sure the tab on the mounting bracket
socket is properly seated in the groove in the
hanger ball (Figure 11).
THE HOOK AS SHOWN IN FIGURE 11 IS ONLY
TO BALANCE FAN WHILE ATTACHING WIRING.
FAILURE TO HANG AS SHOWN IN FIGURE 11
MAY RESULT IN HOOK BREAKING, CAUSING
THE FAN TO FALL. HOOK MUST PASS FROM
INSIDE TO OUTSIDE OF CANOPY
Mounting
Close-to-Ceiling
Screws
Mounting
(Supplied With
Outlet Box)
Hook
Ceiling
Mounting
Bracket
Figure 10
LOCKING SLOTS OF CEILING CANOPY ARE
PROVIDED ONLY AS AN AID TO MOUNTING.
DO NOT LEAVE FAN ASSEMBLY UNATTENDED
UNTIL ALL FOUR CANOPY SCREWS ARE EN-
GAGED AND FIRMLY TIGHTENED.
WHEN USING THE STANDARD BALL/DOWN-
ROD MOUNTING, THE TAB IN THE RING AT THE
BOTTOM OF THE MOUNTING BRACKET MUST
REST IN THE GROOVE OF THE HANGER BALL.
FAILURE TO PROPERLY SEAT THE TAB IN THE
GROOVE COULD CAUSE DAMAGE TO WIRING.
Standard Mounting
Figure 11