DESCRIPTION OF OPERATION
Become familiar with these controls
before operating the unit.
Off (O)/Auto(I) Switch: Turn this
switch to"AUTO (I)" to provide auto-
matic power to the pressure switch
and "OFF (O)" to shut off power at
the end of each use.
Pressure Switch (not shown): The
pressure switch automatically starts
the motor when the air tank pressure
drops below the factory set "cut-in"
pressure. It stops the motor when the
air tank pressure reaches the factory
set "cut-out" pressure.
Safety Valve: If the pressure switch
does not shut off the air compressor
at its "cut-out" pressure setting, the
safety valve will protect against high
pressure by "popping out" at its fac-
tory set pressure (slightly higher than
the pressure switch "cut-out" setting).
Tank Pressure Gauge: The tank pres-
sure gauge indicates the reserve air
pressure in the tank.
Outlet Pressure Gauge: The outlet
pressure gauge indicates the air pres-
sure available at the outlet side of the
regulator. This pressure is controlled
by the regulator and is always less
than or equal to the tank pressure.
Regulator: Controls the air pressure
shown on the outlet pressure gauge.
Turn knob clockwise to increase
pressure and counter-clockwise to
decrease pressure.
Female Tire Chuck: Attaches to the
hose end to be used to inflate tires.
NOTE: To ensure correct tire pressure
use a tire pressure gauge.
Hose Adapter: Attaches to hose end
to allow the use of accessories.
Inflation needle: Attaches to hose
adapter to be used to inflate sport
balls.
Tapered nozzles: Attaches to hose
adapter or blow gun (sold separately)
to be used to inflate toy inflatables/air
mattresses.
High Flow Inflator/Deflator Adapter
Body: Used with inflator/deflator
nozzles it attaches to hose adapter to
inflate or deflate air mattresses, small
boats, inflatable toys, and other inflat-
able items that use a large volume
of low-pressure air. Requires hose
adapter.
Inflator/Deflator Nozzles: Used with
the high flow inflator/deflator adapter
body.
Thread Seal Tape: Apply thread seal
tape to threads of exposed fittings.
Drain Valve (not shown): The drain
valve is located at the base of the air
tank and is used to drain condensa-
tion at the end of each use.
Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart of
this cooling system is an engineered
fan. It is perfectly normal for this fan
to blow air through the vent holes
in large amounts. You know that the
cooling system is working when air is
being expelled.
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the air
outlet.
Check Valve (not shown): When the
air compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the air
compressor reaches "cut-out" pres-
sure, the check valve "closes", allow-
ing air pressure to remain inside the
air tank.
HOW TO USE YOUR UNIT
How to use High Flow Inflator/
Deflator Adapter Body
1.
Choose nozzle to be used to
inflate or deflate.
2.
The high flow inflate/deflate
adapter body attachment has an
"inflation" outlet and "deflation"
outlet. Attach the nozzle to the
preferred outlet.
Nozzle
attached to
"deflation"
outlet
13 - ENG