Connected Wattage
The total power consumption of this device can be up to
2400 W. With this connected load a separate supply line pro-
tected by a 16 A household circuit breaker is recommended.
CAUTION: OVERlOAD:
If you use extension leads, these should have a cable
cross-section of at least 1.5 mm
Do not use any multiple sockets, as this device is too
powerful.
Switching on/off
Switching on:
Move the toggle switch to the "I" position.
The indicator light in the switch lights up.
Switching off:
Move the toggle switch to the "O" position.
The indicator light in the switch goes off.
NOTE: Always use fresh water.
1. Place the machine on a flat surface.
2. Opening the lid
Press the two buttons in the lid at the same time.
Then pull the lid upwards.
3. Then fill in the water (max. 1,7 Litre). You can read the filling
level on the water level indicator of the kettle.
4. Close the lid until you hear it lock in place.
5. Place the kettle flush on the base.
6. Only connect the machine to a properly installed 230 V~,
50 Hz safety socket.
7. Switch on the kettle by pressing the switch.
Switching off/Interrupting Operation
There are two ways to stop/interrupt the boiling process:
The appliance switches off automatically after the water has
boiled.
Move the switch to the "O" position to interrupt or stop the
boiling process.
WARNING:
Do not remove the appliance from the base without
switching it off beforehand. The kettle remains
switched on for as long as the switch is in the "I" posi-
tion.
Always switch the device off before you remove it from
the base! Please also ensure that it is switched off
when you put it back on the base!
WARNING: DANGER Of SCAlDING!
When pouring the water out, keep the lid closed.
During operation the housing becomes hot. Do not
touch it and allow the device to cool down before
storing it away.
Remove the mains plug.
Emptying the water container.
05_WKS5010CB.indd 19
.
2
Use
Mains Cable Take-up Device
The mains cable can be wound up on the base.
Cleaning
WARNING:
Always turn the device off before cleaning it and remove
the mains plug. Wait until the device has cooled down.
Never immerse the device or the base in water or other
liquids.
CAUTION:
Do not use any wire brush or other abrasive objects.
Do not use any acidic or abrasive detergents.
Clean the perforated surface of the spout from the inside
with a nylon brush.
Rinse the water container out with clean water. Then dry it
off with a cloth.
Clean the housing after use with a slightly damp cloth.
Decalcification
The frequency of the decalcifying operation depends on the
hardness of the water and on how often the appliance is
used.
If the machine switches off before the water boils, it probably
needs to be decalcified.
Please do not use vinegar but a commercially available
decalcification agent on the basis of citric acid. Only use the
quantities stated in the instructions.
NOTE:
After descaling the device boil fresh water in it several times
(approximately 3-4 times) in order to remove any residues. Do
not consume this water.
Troubleshooting
It is not possible to switch the machine on.
Possible Cause:
After being used without or with too little water the machine
has not cooled down sufficiently.
Remedy:
Allow the machine to cool down for 15 min.
The machine switches off before the water has boiled.
Possible Cause:
The heated base is coated with too much lime or the circuit
of the plug is overloaded.
Remedy:
Descale the machine as instructed.
Check the mains connection.
19