Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Max. flow rate
spout
handshower
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
Installation Considerations
• For best results, Hansgrohe recommends that this unit
be installed by a licensed, professional plumber.
• Please read over these instructions thoroughly before
beginning installation. Make sure that you have all
tools and supplies needed to complete the installation.
• This trim is for use with rough 10452181 (not included).
The rough must be installed and the finished floor
surface completed and made watertight.
• This unit is not anti-scald. In Massachusetts, or if
required by local plumbing code, install an approved
water temperature limiting device conforming to ASSE
1070 (not available from Hansgrohe).
• Protection against backflow is provided by check valve
and an automatically resetting diverter.
2
15 - 75 PSI (0.1 - 0.5 MPa)
145 PSI (1 MPa)
120°-140° F (48° - 60° C)*
158°F (70° C)*
5.3 GPM (20 L/min)
1.75 GPM (6.6 L/min)
• This showerhead is for use with an automatically
compensating valve rated at 1.3 GPM (4.9 L/min) or
less.
• To prevent scald injury, the maximum output
temperature of the shower valve must be no higher than
120°F (49°C). In Massachusetts, the maximum output
temperature can be no higher than 112°F (44°C).
• Keep this booklet and the receipt (or other proof of
date and place of purchase) for this product in a safe
place. The receipt is required should it be necessary to
request warranty parts.