MCR7
3
Connection
➤ Insert one side of the RJ-11 cable in the socket "To inverter" (fig. 2 2, page 2).
➤ Insert the other side of the RJ-11 cable into the "Remote Port II" of the inverter.
Switching on/off by external signal
The remote control enables the optional switching on/off of the inverter by external signal:
➤ Loosen both Phillips screws and take off the cap (fig. 2 1, page 2).
➤ Set the desired connection on the jumper (fig. 2 3, page 2):
– Jumper open (A): Switching off inverter by positive battery voltage
When a plus signal is present on the control cable, the inverter is switched off (suitable e. g.
for roof air conditioners). If no signal is received, the inverter works in the previously acti-
vated function.
– Jumpers closed (B): Switching on inverter by positive battery voltage
When a plus signal is present on the control cable, the inverter is switched on and remains
on as long as the plus signal is present.
➤ Assemble the cap (fig. 2 1, page 2).
A
NOTICE!
The control cable has to be secured by a suitable fuse (≤ 1 A.)
➤ Connect the control cable (12 V or 24 V) at the remote control connection (fig. 2 4, page 2).
4
Service
➤ With the "On/Off" button (fig. 2 2page 2) switch the inverter on or off.
✓ An acoustic signal sounds.
5
Disposal
➤ Place the packaging material in the appropriate recycling waste bins wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling centre or specialist
dealer for details about how to do this in accordance with the applicable disposal
regulations.