Torque levels
Max. screw capacity
Tool holder
PAP 20 B3* battery
Type
Rated voltage
Capacity
Cells
High-speed battery charger PLG 20 C3*
INPUT
Rated voltage
Rated power
consumption
Fuse (internal)
OUTPUT
Rated voltage
Rated current
Charging time
Protection class
* BATTERY AND CHARGER ARE NOT SUPPLIED
Noise emission value
Noise measurement value determined in accord-
ance with EN 62841. The A-rated noise level of
the power tool is typically as follows:
Sound pressure level
Uncertainty
Sound power level:
Uncertainty
PDSSAP 20-Li B3
1st level 120 Nm
2nd level 150 Nm
3rd level 190 Nm
4rd level 226 Nm
M16
1/4" hexagon socket
LITHIUM ION
20 V
(DC)
4 Ah
10 (80 Wh)
230–240 V ∼ 50 Hz
(AC)
120 W
T3.15A
3.15 A
21.5 V
(DC)
4.5 A
approx. 60 min
II /
(double insulation)
L
= 85.4 dB (A)
PA
K
= 3 dB
PA
L
= 96.4 dB (A)
WA
K
= 3 dB
WA
Vibration emission value
Total vibration values (vector total of three direc-
tions) determined in accordance with EN 62841:
Tightening screws and nuts of maximum permissible
size
Uncertainty
Wear ear muffs!
NOTE
The vibration emission values and the noise
emission values given in these instructions have
been measured in accordance with a standard-
ised test procedure and can be used for
comparison of the power tool with another tool.
The specified total vibration values and the
noise emission values can also be used to
make a provisional load estimate.
WARNING!
Depending on the manner in which the
power tool is being used, and in particular
the kind of workpiece being worked, the
vibration and noise emission values can
deviate from the values given in these instruc-
tions during actual use of the power tool.
Try to keep the vibration load as low as
possible. Measures to reduce the vibration
load are, e.g. wearing gloves and limiting the
working time. Wherein all states of operation
must be included (e.g. times when the power
tool is switched off and times where the power
tool is switched on but running without load).
a
= 9.598 m/s
2
h
K = 1.5 m/s
2