Velleman SG81030 Manual Del Usuario página 9

Idiomas disponibles
  • ES

Idiomas disponibles

Example:
PWD:1234,SENDMS4:9,GoodMorning%
Password
SMS message "Good Morning" will be sent to phone number 4.
Reply message: Success!: CU2200 succeeds in sending message.
Default! NONB: no preset phone number, operation failed.
Default!: Operation failed but phone number exists.
• Relay Output Control
Command: PWD:XXXX,COUTN:Y%
Password
1234
N
Relay output channel (1 ~ 3) (outputs 2 and 3 not available)
Y
1
0
The relay output is N.O. by default.
Command COUTN:1 is not valid when the relay output is triggered by alarm. Reply message will be ST:XXX in
this case.
In the above case, command COUTN:0 is used to reset the relay output after the alarm is triggered.
• Relay Output Delay Time
Command: PWD:XXXX,OUTNDLAY:YYYY%
XXXX
Password
N
Relay output channel (1 ~ 3) (outputs 2 and 3 not available)
YYYY
0000 – 9999 seconds
0000 Turn the output on or off (default)
0005 Turn on the output for 5 seconds and off again
Turn off the output for 5 seconds and on again
The relay output delay time is good for controlling e.g. an electric door lock.
• Operating Voltage Low Level Alarm Message
When the power supply voltage level is below the minimum level at 5.34VDC, the CU2200 will send an alarm
SMS message.
Date
2007-06-15
Time
13:25
ST:001;TM200706121325;V:5.34#
• Operating Voltage Low Level Alarm
This command is used to set the action to be taken once the operating voltage drops below 7.0VDC. Value of
the current operating voltage can be retrieved by command 2.
Command: PWD:XXXX,ADCOUT0:YY,ZZZZ,NNN%
XXXX
Password
YY
00 means alarm not reported to control centre
10 means alarm reported to control centre 1
01 means alarm reported to control centre 2
11 means alarm reported to control centre 1 and 2
CU2200_v5
www.electronicaembajadores.com
1234
Turn on (close) the output
Turn off (open) the output
9
VELLEMAN
loading