CGOLDENWALL B00PQHLF38 Manual Del Usuario página 20

Ocultar thumbs Ver también para B00PQHLF38:
Idiomas disponibles

Idiomas disponibles

Trouble
Grinder does not work
after power on
Motor run slowly, or not
runs, even vibrates,
making noise
Motor cabin over heat
Spark on the carbon
brush surface
Troubleshooting
Cause
Poor contact between the plug and
socket
Poor contact between the lid and
induction switches
Air over- load protector protecting
Carbon brush worn out
Stuck inside
of grinding tank by
material, or foreign subject
Low power voltage
Over load capacity
Material not dry enough
Low power voltage
carbon brush is not smooth
(*Please cut off the power when
Please plug in the power cord and
check whether the power indicator
lights is on.
If the indicator does not light, then
the power cord is faulty.
Push the rods on the both sides to
the end to make sure trigger the
induction switches.
Press the air over- load protector to
restart
Change the carbon brushes on the
both sides
Remove the stuck stuff
Insert the plug directly into the
wall socket instead of the terminal
block. Then try another place to
see if the machine can be turned
on.
Reducing the amount of grinding
to decrease the working pressure.
Dry the material in the sun or bake
it.
Insert the plug directly into the
wall socket instead of the terminal
block. Then try another place to
see if the machine can be turned
on.
Change the carbon brushes on the
both sides
19
Solution
doing following)
loading