TROUBLESHOOTING
Problems
Irregular color
Is the monitor placed or moved close to
a speaker or any other device
incorporating a magnet?
Has the position of the monitor been
changed with the power on?
Wrong picture
Has the picture position, size or
position, wrong
distortion been changed?
picture size
Have the UNDER SCAN or ASPECT
button been pressed?
Front panel
Has the CONTROL LOCK function
buttons and
been set to ON?
knobs do not
Has the monitor's setting been
function
changed to enable control from an
external unit via the REMOTE
terminals?
The following are not malfunctions:
● You may see two horizontal lines on the monitor. They are the
shadows of the "damper lines" that are necessary for composing
the monitor. These lines are not a malfunction.
● About CRT tube reflection (when Zoom mode is used.)
The screen might appear as brownish white. This is due to a
reflection of part of the image on the CRT caused by certain
signal sources, and it is not a malfunction.
When black vertical lines appear on the screen
Black vertical lines may appear on the screen if the aperture grill is tilted as a result of being shaken or jolted during shipment.
DEGAUSS
SCAN
UNDER
MUTING
VOLUME
MENU
CHECK
SCREENS
In this case, try tapping the monitor on the side. If this does get rid of the lines, follow the procedure below.
1. Display a white screen, so that the problem area can be seen clearly.
2. Maximize the "CONTRAST" and "BRIGHT" adjustments, then place a bright white rectangle on the area.
3. After a while, the lines should disappear.
26
Points to be checked
Damper line
(Front view of
UNDER
PULSE
COLOR
MUTING
DEGAUSS
SCAN
CROSS
OFF
SLOT 1
SLOT 2
SLOT 3
POWER
DT-V1910CG shown)
A
B
C
D
E
F
INPUT SELECT
VOLUME
MENU
SCREENS
ASPECT
AREA
CHECK
MARKER
CROSS
PULSE
COLOR
OFF
SLOT 1
SLOT 2
SLOT 3
POWER
A
B
C
D
E
F
INPUT SELECT
ASPECT
AREA
MARKER
(cont'd)
Measures (Remedy)
Move the device away from the monitor.
Press the DEGAUSS button on the front panel to
degauss the screen.
When degaussing, wait more than 30 minutes for
maximum effect.
Adjust the picture size (H. SIZE, V. SIZE) or
position (H. POSITION, V. POSITION) in the
[SIZE/POSI. ADJ.] item in the <SETUP MENU>
screen.
Adjust the picture distortion (PINCUSHION, PIN.
BALANCE, TRAPEZOID and PARALLELOGRAM)
in the [DISTORTION ADJ.] item in the <SETUP
MENU> screen.
It may not be possible to expand the picture due
to the selected input mode. In this case,
adjustment is impossible.
When the UNDER SCAN or ASPECT button is
lit, press each button to invalidate each setting.
Set the CONTROL LOCK function to OFF.
Change the setting of the external control to
control the monitor locally.
● When a bright still image (such as a white cloth) is displayed for a
long period, it may appear to be colored. This is due to the
structure of the cathode ray tube and will disappear when another
image is displayed.
● You may sometimes experience a mild electric shock when you
touch the picture tube. This phenomenon is due to a normal
buildup of static electricity on the CRT and is not harmful.
● The monitor emits a strange sound when the room temperature
changes suddenly. This is only a problem if an abnormality
appears on the screen as well.
● If two or more monitors are operated next to each other, their
images may shake or be distorted. This phenomenon is due to
mutual interference; it is not a malfunction. Move the monitors
away from each other until the interference disappears or turn the
power off on any monitor that is not being used.
DEGAUSS
SCAN
UNDER
CROSS
PULSE
OFF
COLOR
MUTING
SLOT 1
SLOT 2
SLOT 3
POWER
A
B
C
D
E
F
INPUT SELECT
VOLUME
MENU
SCREENS
CHECK
ASPECT
MARKER
AREA
Reference
pages
4
21
5
22
23, 24
DEGAUSS
SCAN
UNDER
CROSS
PULSE
COLOR
OFF
MUTING
SLOT 1
SLOT 2
SLOT 3
POWER
A
B
C
D
E
F
INPUT SELECT
VOLUME
MENU
SCREENS
CHECK
ASPECT
AREA
MARKER