Technical details
Voltage
:
12 V
Current
:
28 A
Connections
: 1x ø 40 mm
: 1x ø 32 / 40 mm
: 1x ø 12 mm
: 1x ø 19 mm (drain)
Capacity of container
Maximum vertical lift
Maximum horizontal displacement : 40 m
Pump capacity at discharge height
of 4 metres
Maximum liquid temperature
Noise level
Protection
Weight
10 Faults
Make sure that the power is disconnected when carrying out any necessary repairs.
Fault
The motor starts spontaneously.
The motor runs continuously or for a long
time.
The motor will not start.
The motor makes a noise but does not run
(does not pump).
The motor starts but stops spontaneously.
Installation and user manual GWDS
24 V
120 V
230 V
14,5 A
6,5 A
1,2 A
: 3,5 litres
: 4 m
: 44 litres/min
: 35˚C for a short period
: 40 dBA
: IP44
: 3,5 kg
Possible cause
Taps are dripping.
The non-return valve is faulty.
The vertical lift is too high / There is too
much water flushing through / There are
too many bends in the installation.
The equipment is not connected or the
power supply is faulty.
The fuse has blown.
The motor is faulty.
The motor is damaged or the condenser is
faulty.
The thermal protection system has been
activated because the waste water is too
hot.
ENGLISH
Solution
Check and repair the taps (replace the
gaskets).
Clean or replace the non-return valve.
Check and change the installation.
Connect the equipment or repair the power
supply.
Mend the fault and replace the fuse.
Consult a qualified engineer.
Consult a qualified engineer.
Allow the motor to cool off for an hour.
The thermal protection system will
automatically switch on.
11