1.9 Flowmeter function (optional)
The machine can be opted with a fl owmeter that allows accurate reading of water consumption that, otherwise, is estimated
upon the rinse pump run time.
Activation is set by the dip-switch (see paragraph 1.11) and from info menu (see paragraph 4.4).
1.10 Anti-fl ooding function (optional)
The machine can be equipped with optional anti-fl ood device that avoids, in case of leakages, room fl ooding. A fl oat, placed in
a tray on the bottom of the machine, detects the water and sends a signal. The machine stops all the functions and generates
an alarm. The tray allows collecting some of the spilled water. The optional has to be set by the service menu (see paragraph
3.11). A load pipe with a water block device is supplied as standard equipment for this optional.
1.11 Dip-switch functions
On the circuit board there are dip-switches that allow enabling/disabling some functions (see photo 1).
#
1
SOFT START WASH PUMP
2
INLET WATER PROBE
3
FLOWMETER
4
TIME FOR OSMOSIS
5
DISABLED
6
DISABLED
7
DISABLED
8
DISABLED
table 1
page 34
Function
Default
OFF
Value set on ON: the wash pump Soft Start is
disabled.
OFF
Value set on ON: The loading water probe reading
is enabled. If the probe is not installed, the machine
generates a probe failure alarm.
OFF
Value set on ON: The inlet water-fl ow reading is
enabled. If the fl owmeter is not enabled in the menu
25
(see paragraph 4.4) or is not installed or is faulty,
the machine generates a signalisation
OFF
Value set on ON: The time-out for the tank and
boiler fi lling is extended (alarms
/
/
/
/
/
/
/
/
photo 1
Note
B1
and E1).