Hilti Nuron SL 10-22 Manual De Instrucciones Original página 23

Ocultar thumbs Ver también para Nuron SL 10-22:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
6.1
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery. → page 14
6.2
Inserting battery
WARNING
Risk of injury by short circuit or falling battery!
▶ Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
▶ Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.
2. Open the lid of the battery compartment (1).
3. Push the battery into the product until it engages with an audible click (2).
4. Check that the battery is seated securely.
5. Close the lid of the battery compartment.
6.3
Removing the battery
1. Press the battery release button.
2. Remove the battery from the product.
6.4
Setting up
3
1. Set the tower light on a level surface.
2. Unlock the tripod legs by pressing tripod lock release (1) and pull the carrying handle down (2) until it
snaps into engagement.
The tower light can be secured to the floor for increased stability.
3. To secure the tower light to the floor, drill three holes corresponding to the position of the tripod legs.
Technical data
Diameter of the holes in the tripod legs
4. Secure the tower light to the floor. Use a type of fastener suitable for the floor. Comply with the operating
instructions of the fastener.
6.5
Adjusting height
1. Open a clamping lever (1).
2. Slide the lamp head up to the desired height (2).
3. Re-close the clamping lever (1).
4. If necessary, repeat steps 1 to 3 for the second telescopic extension.
7
Operation
WARNING
Damaged power cords are a safety hazard! If the supply cord or extension cord is damaged while work
is in progress, immediately disconnect the device and the cord from the electricity supply. Do not touch the
damaged part of the cord.
▶ Regularly check all supply cords. Replace defective extension cords. Have damaged power cords
replaced by a qualified specialist.
Use of a ground fault circuit interrupter (residual current device, RCD) with a maximum tripping current of
30 mA is recommended.
*2384868*
2
4
2384868
6 mm
English
17