Primary side
Primary power supply
Primary power supply frequency
Effective primary consumption
Maximum primary consumption
Fuse primary
Maximum apparent power
Maximum active power
Recommended power generator
Active power in standby (IDLE)
Efficiency at maximum current
Power factor at maximum current
Cos Phi
Secondary side
No load voltage (according standard)
Welding range Max MIG
Welding range Max MMA
Duty cycle at 100%
(10 min cycle at 40°C)
en MIG
Duty cycle at 60%
(6 min cycle at 40°C)
en MIG
Duty cycle at maximum current at 40°C
Miscelleanous
Dimensions (Lxwxh)
Weight
Operating temperature
Storage temperature
Torch connection
Protection index
Insulation class
Standard
WARNING: This power source cannot be used in falling rain or snow. It may be stored outside, but it is not designed for use
without protection during raining.
CITOSTEEL III / CITOPULS III 420-520
(MIG)
(MIG)
en MIG
en MIG
CITOSTEEL III 420
CITOSTEEL III 520
W000383618
W000383619
400 V
400 V
50/60Hz
50/60Hz
18,5 A
28,5 A
26 A
33,9 A
25 A Gg
32 A Gg
18 KVA
23,8 KVA
17,2 KW
22,4 KW
30 KVA
40 KVA
28 W
29 W
87
89
0,96
0,94
0,99
0,99
57 V
73 V
14,8V / 35 V
14,8V / 39 V
15A / 420A
15A / 500A
15A / 420A
15A / 500A
350A
450A
380A
500A
40%
60%
720 x 295 x
720 x 295 x
525
525
34 kg
40 kg
-10° C / +40° C
-10° C / +40° C
-20° C / +55° C
-20° C / +55° C
"Européen"
"Européen"
IP 23
IP 23
H
H
60974-1 &
60974-1 &
60974-10
60974-10
CITOPULS III 420
CITOPULS III 520
W000383663
W000383664
400 V
400 V
50/60Hz
50/60Hz
21,1 A
28,5 A
27,1 A
33,9 A
25 A Gg
32 A Gg
18,9 KVA
23,8 KVA
17,7 KW
22,4 KW
30 KVA
40 KVA
29 W
29 W
87
89
0,93
0,94
0,99
0,99
73 V
73 V
14,8V / 35 V
14,8V / 39 V
15A / 420A
15A / 500A
15A / 420A
15A / 500A
350A
450A
420A
500A
60%
60%
720 x 295
720 x 295 x
x 525
525
36 kg
40 kg
-10° C / +40° C
-10° C / +40° C
-20° C / +55° C
-20° C / +55° C
"Européen"
"Européen"
IP 23
IP 23
H
H
60974-1 &
60974-1 &
60974-10
60974-10
EN
5