Circulating pump
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
2
1
fig. 37
Disconnect the power supply and turn off the gas cock ahead of the valve.
Electrically disconnect the circulating pump, releasing the connections by raising the detail "1" of fig. 37.
Drain the water in the boiler (see "System draining" on page 161).
Unscrew and remove the circulating pump motor assembly (fig. 39)