Siemens RDE100 Serie Instrucciones De Manejo página 13

Ocultar thumbs Ver también para RDE100 Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
P14
X1 External input
(only for RDE100.1)
P15
Temperature limitation
(only for RDE100.1)
P16
Max limitation
temperature for
underfloor heating
(only for RDE100.1)
P17
Window contact
features (only for RDE
100.1)
P21
Button scanning rate
for the capacitive
buttons
(RDE100.1 only)
Note: a shorter
scanning rate means
shorter battery life.
P22
Reload factory
settings
P23
Software version
information
P78
Control behavior
P89
Forward shift on max
P90
Early shutdown max
CB1B1422
0 = No input
1 = External sensor
2 = Digital Input
0 = OFF (default)
1 = ON
25...60 ° C, step 1 ° C or
77...140 ° F, step 1 ° F
Default: 30 ° C
0 = Normally Open Contact
(default)
1 = Normally Closed Contact
0.2 = 0.25 s
0.5 = 0.5 s
1.0 = 1.0 s (default)
1.5 = 1.5 s
0 = OFF (default)
1 = reload
No adjustment possible
0 = On/Off, 1.0K
1 = On/Off, 0.3K
2 = TPI fast
3 = TPI medium
4 = TPI slow (default)
0, 0.5,...24 h
Default: 0 h
0, 0.5,...6 h
Default: 0 h
EN
11
loading