Taurus CIG3FIXMG Instrucciones De Uso página 27

Idiomas disponibles

Idiomas disponibles

Downloaded by: pd-oliana on 07-03-2023 10:29 CET
Main Gas Pipe
Gasket
Nut
Natural Gas
Connection Hose
Figure 1
Figure 2
Ventilation of room
The air needed for burning is received from room air and the gases emitted are given directly in room. For safe
operation of your product, good room ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However, room has a door opening outside, it
is no needed to vent holes.
Room size
Smaller than 5 m³
Between 5 m³ - 10 m³
Bigger than 10 m³
In basement or cellar
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjustmed and turn the knob to the reduced position.
For natural gas connection;
WARNING: Natural gas connection should be done by author-
ized service.
For natural gas connection, place gasket in the nut at the edge of
natural gas connection hose. To install the hose on main gas pipe,
turn the nut. Complete the connection by making gas leakage
control.
Gas hose passage way
Connect the appliance to the gas piping tap in shortest possible
route and in a way that ensure no gas leakage will occur.
In order to carry on a tightness and sealing safety check ensure that the
knobs on the control panel are closed and the gas cylindir is open.
WARNING: While performing a gas leakage check, never use any kind of
lighter, match, cigarette or similar burning substance.
Apply soap bubble on the connection points. If there is any kind of leakage
then it will cause bubbling.
While inserting the appliance in place ensure that it is on the same level
with the worktop. If required adjust the legs inorder the make level with
the worktop.
Use the appliance on a level surface and in a well ventilated environment.
WARNING: Before placint the appliance, check that the local distribution
conditions (gas type and pressure) conform to the product settings.
Nozzle change operation
1. Please use driver with special head for removed and install nozzle as.
(figure 3)
2. Please remove nozzle (figure 4) from burner with special nozzle driver
and install new nozzle. (figure 5)
Figure 3
Figure 4
Ventilating opening
min. 100 cm²
min. 50 cm²
no need
min. 65 cm²
Figure 5
loading

Este manual también es adecuado para:

Cig3fwhmg