Purge
• The system must be purged of any air bubbles by filling
the pump with clean water before turning it on.
• * Remove the drain plug (A). Fill with water until it
reaches the level of the hole and screw on the plug. Only
then can the pump be started.
Never start the pump when the pump
WARNING
is empty If this happens accidentally, turn off the pump
immediately, wait for it to cool down and then fill it using
clean water.
Turn ON
CAUTION
Before turning on the pump, it is essential
to comply with the following points, otherwise it could be
damaged and the guarantee would be invalidated:
• All hoses must be connected, completely untangled and
free of kinks.
• The suction hose with filter must be submerged in the
water source.
• Gasoline and oil levels must be correct.
• The system must be purged as indicated above.
• Press the switch (B).
• Press and release the primer bulb 10 times (C).
• Raise the choke lever (D) to the "closed" position.
• Move the throttle lever (E) to the high-speed position.
• Gently pull the line handle three or four times (F) until you
feel resistance on the line. Then pull hard to start the engine.
CAUTION
Carefully return the handle to its place. Do
not let go, otherwise it will snap back and may be damaged.
• Allow the engine to run for 5 seconds and then lower the choke
lever to the "open" position.
• Always pay attention to the level of the
CAUTION
water source, as during the pumping operation the level
could drop as low as that the end of the suction hose is out
of the water. If so, turn off the pump immediately and correct
the depth of the suction hose. Avoid running the pump
without water, otherwise it may be damaged.
Turn OFF
• Move the throttle lever (E) to the low-speed position.
• Wait a minute or two before the switch (B).
• Move choke lever (D) to "closed" position.
10
ENGLISH
Start up
A
E
B
C
F
D