Sonesse 40 WireFree RTS Li-ion
3.8. BATTERY REPLACEMENT
͉
͉
Contact Somfy for battery model's recommendation.
Precaution
Replacement of the battery by an identical model only, must be carried out by a professional of
the motorization and the automation of the habitat.
Attention
• Do not use tools that could damage the drive when replacing the battery.
• Do not cut or damage the antenna cable.
1) If the drive is fixed to the tube, disassemble the motorised
product to access the self-tapping screws or steel pop rivets
(motor drive wheel side) and remove them.
2) Grab the drive head and pull out the drive by sliding it out of
the motorised product tube.
3) If necessary, remove the ring gear on the actuator tube to
access the two T8 torx screws or cruciform screws and
unscrew the drive head.
4) Remove carefully the drive head from the drive tube taking
care not to damage the wires and disconnect the battery.
5) Grab and remove the used battery by sliding it out of the
drive tube taking care not to damage the wires.
6) Insert and slide the new battery into the drive tube, leaving
the battery connector accessible from the outside of the
tube.
7) Connect the new battery.
8) Insert the drive head using the keying notches on the drive
tube taking care not to cut off the wires.
9) Screw the drive head using the two T6 torx screws or
cruciform screws to the drive tube.
10) Restart the installation in chapter 2.1.3. Drive/tube
assembly.
͉
͉
If necessary, readjust the end limits referring to chapter 2.4.2.
End limit readjustment.
Copyright
©
2019 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
1
2
3
4
5
6
7
8
9
10
=> 2.1.3. Drive/tube assembly
EN