Magmaweld COMPACT EXPERT Serie Manual Del Usuario página 33

Ocultar thumbs Ver también para COMPACT EXPERT Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 225
COMPACT EXPERT SERIES
The following effects will occur if the pressure adjustment screw is overtightened,
A: Suitable wire pressure and conduit dimensions.
left loose or if the wrong wire feed roller is used.
B: The wire is distorted since the pressure lever is too tight.
C: The roller surface is deteriorated due to excessive pressure on the pressure lever.
D: The conduit length of the roller is small for the wire used. Wire form is distorted.
E: The conduit length of the roller is big for the wire used. The wire cannot be transmitted to the welding area.
Figure 10 : Pressure Setting and Roller Selection Mistakes
3.9 Adjustment of Gas Flow
Make the gas adjustment and gas test by lifting the wire feed roller pressure lever!
• Adjust the gas flow with the flow control valve.
• Practical gas flow rate (CO₂, Ar, mixture) is 10 times of
wire diameter.
For example, if the wire diameter is 0.9 mm, the gas
flow rate can be adjusted as 10 x 0.9 = 9 l / min.
• You can use the table on the side for more precise flow
adjustment.
• After adjusting the gas flow, lift the thrust bearing arm
and close the wire feed unit door.
www.magmaweld.com
Mild Steel
and
Flux Cored
Metal Cored
0.8
8 lt/min.
7 lt/min.
9 lt/min.
8 lt/min.
0.9
10 lt/min.
9 lt/min. 10 lt/min. 10 lt/min.
1.0
12 lt/min. 11 lt/min. 12 lt/min. 12 lt/min.
1.2
Operation
33
Stainless
Aluminium
Steel
8 lt/min.
8 lt/min.
9 lt/min.
9 lt/min.
USER MANUAL
EN
loading

Este manual también es adecuado para:

Id 400 mk pulse expertId 400 mkw pulse expert