TECHNICAL DATA
Voltage range .........................7.2-24 V
Quick charge current ...................1,8 A
Maintaining charge .......................50 mA
Battery charging time
1,4 Ah ............................approx 47 min
1,7 Ah ............................approx 57 min
2,0 Ah ............................approx 67 min
2,2 Ah ............................approx 73 min
2,4 Ah ............................approx 80 min
2,6 Ah ............................approx 87 min
Weight without cable ..................500 g
SAFETY INSTRUCTIONS
Please pay attention to the safety instructions in the attached
leaflet!
Do not dispose of used battery packs in the household refuse
or by burning them. Milwaukee Distributors offer to retrieve
old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only System 3000 chargers for charging System 3000
battery packs. Do not use battery packs from other systems.
The following battery packs can be charged with this charger:
voltage
battery
7,2 V
B 7.2-range
9,6 V
B 9.6-range
12 V
B 12-range
14,4 V
B 14.4-range
18 V
B 18-range
24 V
B 24-range
9,6 V
M 9.6-range
12 V
M 12-range
14,4 V
M 14.4-range
18 V
M 18-range
24 V
M 24-range
Do not try to charge non-chargeable batteries with this
charger.
No metal parts must be allowed to enter the battery section of
the charger (short circuit risk).
Never break open battery packs and chargers and store only
in dry rooms. Keep dry at all times.
Please pay attention to the following symbol on the label of
the charger:
This tool is only suitable for indoor use. Never expose
tool to rain.
The battery clamps of the charger are fed by the mains
supply. Do not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new
one.
Before use check machine, cable, and plug for any damages
or material fatigue. Repairs should only be carried out by
authorised Service Agents.
SPECIFIED CONDITIONS OF USE
The quick charger can charge Milwaukee batteries from
7.2 V to 24 V.
Do not use this product in any other way as stated for normal
use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also possible
to connect to sockets without an earthing contact as the
design conforms to safety class II.
5 ENGLISH
rating
No. of
(of storage battery)
battery
cells
1,4 Ah
6
1,4 Ah
8
1,2 Ah
10
1,4 Ah
12
1,4 Ah
15
1,4 Ah
20
2,2 Ah
8
2,2 Ah
10
2,2 Ah
12
1,4 Ah
15
1,4 Ah
20
BATTERIES
New battery packs reach full loading capacity after 4 - 5
chargings and dischargings. Battery packs which have not
been used for some time should be recharged before use.
General note concerning NiMH batteries:
The capacity of the battery is reduced when the temperature
falls below -10°C.
Long-term storage at temperatures higher than +40°C may
have negative effects on the capacity of the battery.
CHARACTERISTICS
After inserting the battery into the reception of the charger the
battery will automatically be charged (yellow control lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(flashing yellow lamp), charging will begin automatically once
the battery reaches the correct charging temperature
(5°C...45°C).
Standard charging time is approximately 38 minutes (1.4 Ah
battery). Charging time varies depending on the battery
temperature, charge needed and the type of battery pack
being charged.
As soon as charging is completed, the charger switches over
to "trickle" charge to maintain the full capacity (green control
lamp is illuminated continuously)
It is not necessary to remove the battery after charging. The
battery can be stored permanently in the charger without the
danger of being overcharged.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in
conformity with the following standards or standardized
documents. EN 60335, EN 55014-1, EN 55014-2, EN 61000-
3-2, EN 61000-3-3, in accordance with the regulations 73/23/
EEC, 89/336/EEC
Manager Product Development
MAINTENANCE
If the supply cord of this appliance is damaged, it must only
be replaced by a repair shop appointed by the manufacturer,
because special purpose tools are required
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service
agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the ten-digit No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
The battery clamps of the charger are fed by
mains supply. do not touch the tool with
conducting objects.
Please read the instructions carefully before
starting the machine.
Volker Siegle