HANDLE REVERSING INSTRUCTIONS
1. Remove the allen wrench from the panel
installation screw kit envelope
2. Loosen the set screw using the allen wrench.
Remove the handle and flip it around so the logo is
facing the other way.
set screw
LOOSEN
3. Place the handle caps over the fasteners of the
door. Take care to support the handle so it doesn't
fall and scratch the appliance finish. Make sure
both handle caps are resting on the face of the
door.
fastener
4. Lock one end of the handle into position by
tightening the set screw in the handle cap with the
set screw
5. Keep supporting the handle as you lock the other
end of the handle into position by tightening the set
18
Installation Instructions
set screw
handle cap
set screw
PLUMBING - DRAIN PUMP
Drain Installation
A drain pump is available for this ice machine. The
GEApplianceparts.com or by calling GE
Appliances at
GEAppliances.ca or call 800.661.1616.
PLUMBING - GRAVITY DRAIN
Drain Installation
NOTICE
Restrictions in the drain
system to the machine will cause water to back
up into the ice storage bin and melt the ice.
Gravity drain tubing must be vented, have no
kinks, and slope to the building drain. Air gaps
are typically required by local codes.
A: Floor Drain Located Under Unit
1. Place the unit (ice machine) in front of the
installation opening. Adjust leveling legs to the
appropriate height.
2. Remove the left side (when facing the product)
access panel to the drain connection.
3. Remove the plastic cover/ plug in the base pan
of the unit.
4. Remove the clamp and rotate the barbed
elbow on the drain tube so it will drain
through the base pan and into the floor drain.
Re-secure the clamp.
5. Reinstall the access panels.
6. While trying to locate the unit drain as close as
possible to the floor drain, carefully push the
unit into place.