Problem
Motor runs, but poor
suction.
Motor stops during
operation
Machine blows dust.
Abnormal sound from
machine.
EC Declaration of Conformity
We hereby declare that DC Tromb Twin complies with the following regulations and standards: 2006/42/EC, 2014/35/EC,
2014/30/EC, EN 60204-1:2006/A1:2009, EN1822-1: A1:2009.
Dustcontrol AB
Anna-Lena Berg / CEO
2021-05-03
20
Cause
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
The pump is rotating in the wrong
direction.
Motor overheated
Filter loose or damaged.
Tromb Twin, Art.nr. 99039-B
Action
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Let an electrician change the phase.
Make sure the machine is not throttled and
wait for it to cool down (about 30 min)
Check and replace as necessary.
Book service.
Peter Söderling / Technical Manager
2021-05-03