Connecting the transformer
• With the wiring terminal shroud off, find the two terminal holes labeled
"24VAC" . Make sure the transformer is not plugged in . Insert one of the two
power leads from the transformer into each terminal .
• It will be necessary to open the terminal to allow for wire insertion or
removal . To do this you will need to use a small phillips head screwdriver .
• Plug in transformer [See Figure 18].
WARNING: DO NOT LINK TWO OR MORE CONTROLLERS TOGETHER WITH ONE
TRANSFORMER.
• Slide the shroud back on.
SENSOR
COM
Figure 18: Connecting the Transformer
23
1
2
3
4
5
6
PUMP
24VAC
rain sensor
A rain sensor or other type of micro-switch weather sensor may be connected
to the controller . The purpose of the sensor is to stop watering when
precipitation is sufficient .
rain sensor Bypass
The controller is equipped with a sensor override "on/off" switch . This switch is
for use during service so the controller can be operated even if the rain sensor
is in active mode .
Note: If the rain sensor "on/off" switch is in the "on" position
and no sensor is connected the controller/controller will not
operate. To resume controller operation place the switch in the
"off" position.
Connecting a rain sensor (not included)
The controller is equipped with a sensor override "on/off" switch . This switch
is for use during service so the controller can be operated even if the rain
sensor is in active mode [See Figure 19] .
Connection
• Connect the rain sensor wires to the wiring terminal ports (two) marked 'sensor'
[See Figure 20] .
• Place the sensor on/off switch to the "on" position to begin operation.