6. Insert the tip (1) into the slot on the tip guard.
7. Thread the tip guard onto the gun. Position the tip guard in the desired
spraying position, then tighten securely.
The arrow on the tip handle should be pointing in the forward
i
direction for spraying.
oPERAtIoN
1. Make sure the arrow on the tip handle is pointing in the forward direction
for spraying.
2. Start the sprayer. Refer to the instructions in the sprayer's Owner's Manual.
3. Adjust the fluid pressure on the sprayer until the spray is completely
atomized. Always spray at the lowest pressure necessary to get the desired
results.
The spray tip determines the size of spray pattern and coverage.
i
When more coverage is needed, use a larger tip instead of increasing
fluid pressure.
4. To clear a clogged tip:
a. Rotate the tip 180º so that the arrow on the tip handle is pointing opposite the
spray direction.
b. Trigger the gun once so that the pressure can blow the clog out.
Never pull the trigger more than once with the tip in the reverse
position.
Attention
c. Continue this procedure until the tip is clear of the clog.
cHANGING A tIP
Tips can be removed and replaced easily without disassembling the gun.
Never attempt to change or clean the tip or tip guard without first
performing the "Pressure Relief Procedure."
1. Perform the "Pressure Relief Procedure" described in the sprayer's Owner's
Manual.
2. Remove the tip from the slot on the tip guard.
3. Insert the new tip into the slot on the tip guard. The arrow on the tip handle
should be pointing in the forward direction for spraying.
6
GB
RX-80