PELLET FIREPLACE
(Rev. 15/10/2013)
13. CONNECTING TO THE EXTERNAL AIR INLET
When connecting the stove with an external air inlet you will get an exceptional level of comfort and operation
softness. The stove will properly burn even in case you cannot connect it to an external air inlet but get the
combustion air from the room. The UNI 10683 shows the minimum air volume in the room to be respected. For all
other countries, respect all local and national regulations in force.
The air inlet diameter should be not less than 100 millimeters and the maximum piping length is 1 meter and one 90°
bend.
14. ELECTRICAL CONNECTION
Check for the wall plug to be adequate to the stove electrical requirements: 230V/50Hz e 400Watt. Make sure the
electrical cord doesn't get in touch with any hot part of the stove, doesn't run over the smoke connection, a proper
earth is available and a proper circuit breaker is fitted. In case of irregular power supply (normally in remote or
mountain areas), do not worry bat your stove is protected with two 5X20 4A STD between the main switch and the
cord plug on the rear panel.