MODEL
L ( m )
AEI1G30
EG
Supply power wire A:
Multipolar electric wire. Size and length of the suggested electric wire are showed on table "electrical data". The wire
must be Mod. H07RN-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between
the fixing point and the terminals allows the straining of the conductors L, N before that of the grounding.
Connecting wire B (SHIELDED):
Bipolar electric shielded wire; size and length of the suggested electric wire are showed on table "electrical data".
The wires have not to be lighter than Mod. H05VVC4V5-K (according to CEI 20-20 CENELEC HD21).
Connecting wire C (with ground conductor):
Multipolar electric wire; size and length of the suggested electric wire are showed on table "electrical data". The
wires have not to be lighter than Mod. H07RN-F (according to CEI 20-19 CENELEC HD22).
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene
l
(min. thickness 8mm).
NARROW TUBE
OUTER DIAMETER
6,35 mm
PVC pipe for condensate drain pipe (ø int.18mm) in length suitable to let the condensate flow into the outside drainage.
l
Anti-freeze oil for flare connections (about 30g.).
l
Electric wire: use insulated copper wires of size and length as shown at paragraph "SYSTEM WIRING DIAGRAMS".
l
TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
TOTAL TUBING LENGHT
AT SHIPMENT (m)
REQUIRED AMOUNT OF ADDITIONAL REFRIGERANT
For tubing 1/4 " - 3/8" = 15g/m
For tubing 1/4 " - 1/2" = 20g/m
LIMIT OF ELEVATION DIFFERENCE - OUTDOOR UNIT/INDOOR UNIT: 10m (H)
No additional charge of compressor oil is necessary.
LENGTH, SIZE WIRES AND DELAYED FUSE
A
2
S ( mm
)
L ( m )
15
1,5
MIN. THICKNESS
0,8 mm
H
7,5
B
2
S ( mm
)
L ( m )
15
0,75
OUTER DIAMETER
9,52 mm
TOTAL TUBING LENGHT
WITH ADDITIONAL REFRIGERANT (m)
15
4
C
2
S ( mm
)
15
1,5
LARGE TUBE
MIN. THICKNESS
0,8 mm
H
10 A