PROGRAMMING MODE - SETUP MODE

27. How to set drop count

can be used to set the number of drop counts. Drops occur while the machine checks for
balancing of the load as the cycle enters higher RPM.
Enter setup mode.
You will see LqC1
NOTE
• Drop counts 25~45: After dropping the selected amount of counts, UE will not occur. The cycle
will end immediately or after spinning at a low RPM.
• Drop counts 50: After dropping the selected amount of counts, UE will occur. The cycle will end
after shut down time. Refer to How to set shut down time after UE.
Press the Hot button.
Press the Warm or the Cold button until
in the display.
Press the Start button.
Press the Warm or the Cold button until
in the display.
Press the Start button.
Display default drop count.
Press Warm(+) or Cold(-) button to select time between
25 and 50. (Unit of drop count : 5)
Press the Start button.
The machine sets up the drop count, then advances to
the next process automatically.
1. Continue to set up the next mode.
2. Stop the change of setup value and go back to ready
mode.
• Coin type - Turn on/off toggle switch.
• Card type - Pull the service card.
• All types - Push the Hot button twice.
Button
Display
appears