Installation • Operation
Specifications
Power supply required. . . . . . . . . . . . . . . . . . . . . . . .115V, 60 HZ.
Liquid Temp. Range. . . . . . . . . . . . . . . . .Less Than 120°F (48.9°C)
Horsepower. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2
Maximum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1420 GPH
Suction, Discharge Thread. . . . . . . . . . . . . . . . . . . . . . . 3/4" FNPT
Maximum Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 PSI
Performance
Performance (in GPH) at Discharge Pressure (PSI)
Distance to
pump above
water
5
0 ft.
1420
5 ft.
1350
10 ft.
1280
15 ft.
1210
20 ft.
1130
25 ft.
1060
Location of Unit
Locate pump as near as possible (vertically) to water
source, to keep suction lift (distance form water to pump)
as low as possible. Place pump on level support. Protect
against excess moisture and flooding.
Piping
Both suction and discharge ports are tapped for 3/4"
pipe. If using hoses, use hose to pipe thread adapter. To
prevent suction line collapse, use pipe or reinforced hose
only for suction line. Install strainer or puddle gulper on
end of suction line. Inspect and clean strainer frequently
(Figure 1). Plastic pipe can be used for all installations.
Electrical
Risk of electric shock . Can shock, burn or
kill. Unplug pump before servicing it. Do not handle
pump or attempt to work on pump with wet hands or
while standing on wet or damp floor.
Plug pump into 115 Volt, 60 Cycle outlet only. Pump is
equipped with 3-wire, grounded, cord and plug. Do not
modify or remove plug. Plug in to properly grounded,
grounding type outlet only. Make sure pump circuit
meets National Electrical Code. To avoid dangerous
electrical shock hazard, keep cord dry at all times.
Shown
10
20
30
1320
1100
850
1240
1050
800
1170
980
740
1100
920
570
1030
860
500
960
780
430
NOTICE Pump motor is equipped with carbon brushes
with a normal operating life of about 300 hours. One
extra set of brushes is included. Replacement brushes are
available from your dealer. Motor brushes not included
in warranty.
Risk of fire . Incorrectly mounted brushes
may cause fire. Be sure curve on end of brush matches
curve on commutator.
Operation
NOTICE Do not run pump dry. Running pump without
40
water can damage impeller and may damage seal,
550
causing leaking or flooding, and will void warranty.
480
430
360
300
240
Figure 1 - Install the adapters and connect the inlet and
discharge hoses.
Figure 2 - Remove the priming plug and fill the pump
body with water. The pump must be full of water
before you start it!
Discharge hose or
plastic pipe
3/4" NPT to
Hose Adapter
O U
T
I N
Reinforced Inlet Hose
or Plastic Pipe
O U
T
I N
4
5608 0407