Product Safety Information
Intended Use:
These tools are designed to remove and install threaded fasteners.
For additional information refer to Air Pulse Tool Product Safety Information Manual
Form 04584983.
Manuals can be downloaded from www.ingersollrandproducts.com
Product Specifications
Model
Style
QS50P3
Pistol
QS50PQ1
Pistol
QS60P3
Pistol
QS60PQ1
Pistol
QS70P3
Pistol
QS70PQ1
Pistol
QS80P3
Pistol
† K
= 3dB measurement uncertainty
pA
*K= Vibration measurement uncertainty
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install
a properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any
hose coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 16585747 and table on page 2. Maintenance frequency is shown in a
circular arrow and defined as h=hours, d=days, and m=months of actual use. Items identified as:
1. Air filter
2. Regulator
3. Lubricator
4. Emergency shut-off valve
5. Hose diameter
After each 150,000 cycles, or as experience indicates, drain and refill the Impulse Unit Drive
Assembly using the Fluid Replacement Kit (Part No. EQ106S-K400). Lubricate the hex drive and
the output shaft before assembly.
47116942_ed2
Drive
Type
Size
Square
3/8"
Quick Change
1/4"
Square
3/8"
Quick Change
1/4"
Square
3/8"
Quick Change
1/4"
Square
3/8"
Free
Sound Level dB(A)
Speed
(ISO15744)
rpm
† Pressure (L
4300
67.4
4300
67.4
5,300
71.0
5,300
71.0
6,800
76.0
6,800
76.0
6,800
76.4
6.
Thread size
7.
Coupling
8.
Safety Air Fuse
9.
Oil
10. Grease
EN
Vibration (m/s²)
(ISO28927)
)
Level
*K
p
<2.5
---
<2.5
---
<2.5
---
<2.5
---
2.9
1.4
2.9
1.4
3.1
0.7
EN-1