Startup
Check that the filter and flushing water pipe have
3
been properly installed.
Slowly open the stop valves up- and downstream of
the filter. Deaerate the pipework at the next bleed
point downstream of the filter, and drain water briefly.
Check the seals of the installation and filter for leaks.
Insert the cable plug connector of the power supply
unit into the socket (24 V).
Plug in power supply (3) unit to main. The first
24 V
back-washing cycle is performed automatically
(during backwashing the illuminated segments on
the display turn).
The factory setting
7.1
Start up Infinity A only
The required backwash interval must be set on
the filter.
The setting is made with the Set key
Press Set for 5 sec.
Display
Set
Display dots flash; device is in programming mode
Pressing the Set key again steps up the number of
h (hours) or d (days).
The hours h run from 1 - 24, followed by days d from
2 - 56, followed by the hours again etc.
Press the Set key until the desired value has been
set.
The value is saved 10 seconds after the last input.
The display dots disappear. The unit backwashes.
The filter is ready for use.
(7 days) appears.
(7 days) appears