1. Do not place propane supply tank(s) inside
any structure. Propane supply tank(s)
must be placed outdoors.
2. Heaters with a maximum input over
6,000 Btu/Hr shall not be installed in a
bathroom. Heaters with a maximum input
over 10,000 Btu/Hr shall not be installed
in a bedroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See
Air for Combustion and Ventilation, pages
6 and 7. If heater keeps shutting off, see
Troubleshooting, page 19.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
MODEL
Ignition
Gas Type
BTU/Hr (available)
Pressure Regulator Setting
Inlet Gas Pressure*
(inches of water)
Heater Weight
Shipping Weight
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
4
SPECIFICATIONS
MN1PHG
Piezo
Natural
10,000
6" W.C.
Max 10.5"
Min 7"
13 lbs
15.7 lbs
Heater Dimensions (HxWxD) 21.2" × 15.79" × 6.85"
Carton Dimensions (HxWxD) 22.83" × 17.95" × 8.23"
www.usaprocom.com
SAFETY
7. For manual controlled models, always run
heater with control knob at the ON, locked
position. Never set control knob between
locked positions. Poor combustion and
higher levels of carbon monoxide may
result.
8. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
9. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
10. Turn off heater and let cool before servic-
ing. Only a qualified service person should
service and repair heater.
11. Operating heater above elevations of
4,500 feet could cause pilot outage.
12. To prevent performance problems, do not
use propane fuel tank of less than 100 lbs.
capacity.
ML1PHG
Piezo
Propane
10,000
10" W.C.
Max 14"
Min 11"
13 lbs
15.7 lbs
MN1PTG
ML1PTG
Piezo
Piezo
Natural
Propane
10,000
10,000
6" W.C.
10" W.C.
Max 10.5"
Max 14"
Min 7"
Min 11"
14 lbs
14 lbs
16.7 lbs
16.7 lbs
200314-01D