Idiomas disponibles

Gas Control Knob Setting
Electric gas ignition
The gas burner use an electric ignition device located near
each burner that by means a spark igniters ensure its surface
light automatically.
Models with standard ignition
The electric ignition automatically light the surface burners
when the control knobs are turned to LITE position.
To set:
1. Push and turn knob counter clockwise to "LIGHT", all four
or five spark plugs will generate a clicking sound (spark),
however only the burner with the control knob turned to
LIGHT will produce a fla me.
2. Turn knob anywhere between Hi and LO (in this position
the sparking will stop). In case flame goes out repeat the
step 1.
Models with automatic re-ignition
The electronic auto re-ignition, lights the surface burners
when the control knob are turned at any valve rotation that
admits sufficient gas flow to support a flame.
If any burner flame goes out due to a draft or other adversity,
the igniter automatically sparks on all burners to relight the
flame.
NOTE: this feature is provided as a convenience and is not
intended as a safety feature.
To set:
• Push and turn knob counter clockwise everywhere, all
four or five spark plugs will generate a clicking sound
(spark), however only the burner with the control knob
turned from HI _ LO wi ll produ ce a flame and reignite
automatically if the flame go es out.
3 - Gas Cooktop Operation
WARNING
• Do not operate a burner using empty cookware or
without cookware on the grate.
• Do not touch the burner when the igniters are clicking
(sparking).
• Do not let the burner flame extend beyond the edge of
the pan.
• Turn off all controls when not cooking.
Failure to follow these instruction can result in personal
injury or fire.
Gas burners
The gas burners design of these cooktop models, allow
a pleasing option for cooking where size, power and
simmering are a primary concern.
Burners with one ring flame
These gas burner line is engineered to match a wide size
and power capacity. The use of this burner is very simple;
just push and turn the knob counter clockwise and set to the
desired position from Hi to LO heat level (see chart guide
when setting heat level). Its ignition device can be standard
or with automatic re-ignition.