4
84
34
1998 / 1999
R 125 E
1
Let the heater cool down.
2
Remove the removable tank I from the heater and remove the fuel filter.
Some drops may leak from the filter; keep a cloth at hand. Store the fuel fil-
ter and the removable tank outside the heater.
3
Always move the heater in an upright position.
4
Make the fixed tank empty with a fuel pump before transportation or in case
of wrong or dirty fuel. First remove the fuel filter and then insert the fuel
pump into the empty fixed tank. Follow the same procedure if the fuel tank
contains water.
J
SPECIFICATIONS
Ignition
Fuel
Capacity (kW)*
Suitable space min. (m3/m2)**
Fuel consumption (l/hr)*
Fuel consumption (g/hr)*
Burning time per tank (hr)*
Capacity removable tank (litres)
Weight (kg)
Dimensions (mm) (including base plate)
Required batteries
Wick type
*
At maximum setting
**
Specified values are indicative
K
WARRANTY PROVISIONS
Your heater comes with a 24-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
1
We expressly dismiss all other claims for damages, including consequential
damages.
2
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
3
The warranty will no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
4
The warranty will not apply to parts that are subject to normal wear, such as
the batteries, the wick and the manual fuel pump. See for the complete list of
parts excluded from warranty on Qlima.com/warranty.
R 236
electrical
paraffin
2.6
90/36
0.271
217
15.5
4.2
9.6
width 567
depth 302
height 489
3V D.C. (R20 x 2)
P