Work Pro W WFS 1200 Manual De Uso página 6

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN
7. Iris: Modulating the diameter of hole for light passing, it is possible to modify the diameter of round light spot.
Trouble
The lamp pipe does
not discharge
The trigger does not run. We can
noise when the switch is pressed
The trigger runs well,
The contact of output cable is not
but the lamp does
well or the lamp contact is not
not light
OPERATING
1. Light cutting instrumment: Using for light cutting instantaneously, to
make the manual frequency flashing effect or light cutting function
(indicating that the lamp`s brightness is kept, whereas do not let the
Iris
light out from light door).
2. Color temperature slice: When using this color temperature slice, the
temperature of the light source can be dropped from 7200ºK to 3200ºK
3. Color slice 1: Cyan
4. Color slice 2: Yellow
5. Color slide 3: Purple
6. Different effect of mixing color can be get through using to pieces of
color slice simultaneously.
Reason
No voltage input
Theballastt does not run
Not turn on the lamp switch
hear the high frequency pulse
under normal condition.
The circuit connect not well
The lamp is broken
well
Turn off lamp just now
Check parts
Check the switch of ballast
Check the power swtich of ballast
Check the position of the switch
Check wheter there is input
voltage of AC
check all connections
There is high frequency pulse
current between the electrodes
of light pipe
Check corresponding parts
PAG. 5
User Manual/Manual de Instrucciones
TRIGGER REPLACING PROCESS
1. Ensure that the power cables are
and switch in the ballast are off.
2. Loosen the cover board screw on
the trigger and pull out it.
3. Remove the bad trigger and install
the same type new trigger.
4. Especially notice that the wire order
connecting to the trigger can not
be wrong.
5. Recover the board on the trigger
and tighten the screw.
Solution
Turn on the switch
If the power switch is turned on,
the cooling fan and lamo ought to
run
Turn on the switch
If the voltage is normal, it is
possible that the trigger is invalid,
replace it; if there is not voltage
or it is abnormal, please check
the rectifier part
Corresponding repair
Replace with new lamp
Repair
Restart again after waiting for 15
minutes
WFS 1200
Tabla de contenido
loading

Tabla de contenido