Select the required parameter by rotating the encoder to bring
it within the central quadrant (2).
The value and the unit of measurement of the selected param-
eter are shown alongside (3).
Activate the regulation of the selected parameter by pressing the
encoder button.
3a Parameter selection bars
Adjust the value of the selected parameter by rotating the encoder.
Confirm the change made by pressing the encoder button.
Exit the quick choice menu by pressing button (1).
PROCESS
QUICK CHOICE MENU
MMA
ARC AIR
MIG/MAG
The parameters of the quick choice menu can be personalised
(consult the "Interface personalisation" section).
The activation of functions different from the default ones
changes the number and the type of parameters in the quick
choice menu.
34
3.8 Set up
Permits set up and adjustment of a series of additional param-
eters for improved and more accurate control of the welding
system.
The parameters present at set up are organised in relation to the
welding process selected and have a numerical code.
Entry to set up: by pressing the encoder key for 2 sec. (the
central zero on the 7-segment display confirms entry).
Selection and adjustment of the required parameter: by
turning the encoder until displaying the numerical code relating
to that parameter. If the encoder key is pressed at this point,
the value set for the parameter selected can be displayed and
adjusted.
Exit from set up: to quit the "adjustment" section, press the
encoder again.
To exit the set up, go to parameter "O" (save and quit) and press
the encoder.
List of set up parameters (MMA)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Welding current
Permits adjustment of the welding current.
Parameter set in Amps (A).
Minimum 6A, Maximum Imax, Default 100A
3
Hot start
Allows adjustment of the hot start value in MMA.
Permits an adjustable hot start in the arc striking phases,
facilitating the start operations.
Parameter set as a percentage (%) of the welding current.
Minimum Off, Maximum 500%, Default 80%
4
Arc force
Allows adjustment of the Arc force value in MMA.
Permits an adjustable energetic dynamic response in
welding, facilitating the welder's operations.
Parameter set as a percentage (%) of the welding current.
Minimum Off, Maximum 500%, Default 30%
40
Current reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the "Interface personalisation" section).
41
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the "Interface personalisation" section).
44
Regulation step
Allows the regulation of a parameter with a step that can
be personalised by the operator.
Minimum 1, Maximum Imax, Default 1