• When unit is on, press the Timer button to activate the auto STOP function.
When the unit is off, press this button to activate the auto START function.
• Press the (+) or (-) button to change the time by 0.5 hour increments, up
to 10 hours or by 1 hour increments up to 24 hours. The control panel will
then count down time remaining until START or STOP.
• The time selected will be stored within 5 seconds and the main display will
automatically return to its previous state.
• When the auto START or auto STOP functions is set the Timer indicator is
lit identifying that ON or OFF timers are programmed.
• Turning the unit ON or OFF at any time or changing the timers setting to
0.0 will terminate the Auto Start/Stop function.
• When the control panel window displays code "P2", the Auto Start/Stop
function will be terminated.
NOTE: The timer function can either be set to ON or OFF.
Setting ON and OFF simultaneously is not possible.
ION
Press the "ION" pad to switch on or off the ionizer. Ions will be released in the atmosphere
to purify the air and remove unpleasant and unhealthy particles. By pressing once again this
function will be terminated.
INDICATIONS
Bucket Full Indicator
Indicator "Full Water Tank" turns red following a beep alert when bucket is full, removed, or
misplaced.
• The water level control switch shuts off the dehumidifier when the bucket is full,
removed or misplaced
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue
to run until the frost disappears. In this case the display of the unit will show the P1 code.
• This function not only ensures the safe and appropriate operation of the
dehumidifier but is also more efficient and economical in its performance
NOTE:
• When Auto Defrost is operating, the unit may cause some
• Do not turn the dehumidifier off when auto defrost is
EN
noise of the refrigerant fluids flowing, this is normal.
operating.
11